Skip to main content

Executed by ANUBX

Wet lay-up preservation of an 8-inch multiphase flowline

A 1.6 km carbon steel flowline for an Egyptian operator was kept in wet lay-up for 159 days. Corrosion coupons retrieved at the end showed an average rate of 0.0154 mm/y.

Asset
8-inch multiphase flowline, 1.6 km, carbon steel
Client
An Egyptian operator
Lay-up
Wet lay-up, chemically treated and pressurized
Period
December 2025 to June 2026, 159 days

Scope

The flowline carries wet gas and condensate. After a successful hydrostatic test it was placed in wet lay-up straight away.

The line has a buried low point and no permanent pig launchers or receivers, which shaped both the preservation and the later return to service.

ANUBX delivered the specifications, the execution procedure, consultation during execution, inspection, monitoring, coupon retrieval and the close-out report.

Method

  1. Treat the fill waterAn oxygen scavenger, a film-forming corrosion inhibitor and a biocide were dosed into the lay-up water.
  2. Pressurize and holdThe filled line was pressurized and left under positive pressure for the lay-up period.
  3. Monitor with couponsTwo carbon steel corrosion coupons were installed at the inlet on the first day.
  4. Retrieve and measureAfter 159 days the coupons were retrieved, cleaned to ASTM G1 and weighed by the operator's own laboratory.

Results

Both coupons fell in the band that NACE/AMPP SP0775 classes as excellent corrosion control.

Corrosion coupon results after 159 days
CouponExposureRate (mm/y)Rate (mpy)Class
Coupon 1159 days0.01470.579Low
Coupon 2159 days0.01610.634Low
Average159 days0.01540.606Low
  • A black protective film formed on the coupons within 24 hours of filling.
  • The film was still intact and adherent at retrieval, with no dominant red rust.
  • The two coupons agreed closely, which points to low, uniform corrosion.
Average corrosion rate against the SP0775 bands
0.606 mpyMeasured averageExcellent
  1. Excellent: Up to 1 mpy. Measured average: 0.606 mpy
  2. Acceptable: 1 to 3 mpy
  3. Marginal: 3 to 5 mpy
  4. Unacceptable: Above 5 mpy

Corrosion rate (mpy)

Bands per NACE/AMPP SP0775: up to 1 mpy excellent, 1 to 3 acceptable, 3 to 5 marginal, above 5 unacceptable.

Photo record

New bare steel corrosion coupons mounted in their holder before installation
Installation day. New bare steel coupons.
Coupon covered by a uniform black film after 24 hours in the treated line
24 hours. A uniform black film on the coupon.
Coupon at retrieval after 159 days, still covered by an adherent black film
159 days. The film is intact at retrieval.
The two coupons after laboratory cleaning, with no visible metal loss
After laboratory cleaning. No visible wastage.

What the client received

  • Preservation specifications and the execution procedure.
  • Consultation during execution, with inspection and monitoring.
  • Coupon retrieval and a close-out report with the data, photographs and engineering assessment.
  • A return-to-service sequence with a sampling plan: drain, fresh-water flush, low-point liquid removal, nitrogen drying and a staged first gas-in.

Standards applied

  • ASTM G1: coupon cleaning
  • ASTM G31: corrosion rate calculation
  • NACE/AMPP SP0775: coupon monitoring and classification

Planning a lay-up or a long shutdown?

Share the asset, the duration and the conditions.

Visit our LinkedIn company page
Contact us on WhatsApp